Urine Culture, Prenatal, With Group B Streptococcus Susceptibility Reflex*

Create a Free Account to View Prices

Turnaround Time: 2 - 4 days
CPT Code:

87086

Test Type: Vacutainer® gray-top urine culture transport tube

Overview:

Evaluation of pregnant women for asymptomatic bacteriuria has been recommended.1

A single culture is about 80% accurate in the female; two containing the same organism with count of 105 or more represents 95% chance of true bacteriuria; three such specimens mean virtual certainty of true bacteriuria.2 If the patient is receiving antimicrobial therapy at the time the specimen is collected, any level of bacteriuria may be significant. When more than two organisms are recovered, the likelihood of contamination is high; thus, the significance of definitive identification of the organisms and susceptibility testing in this situation is severely limited. A repeat culture with proper specimen collection, including patient preparation, is often indicated. Cultures of specimens from Foley catheters yielding multiple organisms with high colony counts usually represents colonization of the catheter and not true significant bacteriuria. Most laboratories limit to two the number of organisms that will be identified when recovered from urine. Similarly, most do not routinely perform susceptibility tests on isolates from presumably contaminated specimens. Failure to recover aerobic organisms from patients with pyuria or positive Gram stains of urinary sediment may indicate the presence of mycobacteria or anaerobes.

1. Verani JR, McGee L, Schrag SJ, et al. Prevention of perinatal group B streptococcal disease—revised guidelines from CDC, 2010. MMWR.
2010 Nov 19; 59(RR-10):1-32. PubMed 21088663

2. Stamm WE, Hooton TM, Johnson JR, et al. Urinary tract infections: From pathogenesis to treatment. J Infect Dis. 1989 Mar; 159(3):400-406 (review). PubMed 2644378

Cavagnolo R. Evaluation of incubation times for urine cultures. J Clin Microbiol. 1995 Jul; 33(7):1954-1956. PubMed 7665682

Clarridge JE, Pezzlo MT, Vosti KL. Laboratory diagnosis of urinary tract infections. In: Weissfeld AS, ed. Cumitech 2A. Washington, DC: American Society for Microbiology; March 1987.

Joho KL, Soliman H, Weinstein MP. Comparison of one-day versus two-day incubation of urine cultures. Diagn Microbiol Infect Dis. 1995 Jan; 21(1):55-56. PubMed 7789098

Ronald AR, Nicolle LE, Harding GK. Standards of therapy for urinary tract infections in adults. Infection. 1992; 20(Suppl 3):S164-S170,S175-180. PubMed 1490743

Stamm WE. Criteria for the diagnosis of urinary tract infection and for the assessment of therapeutic effectiveness. Infection. 1992; 20(Suppl 3):S151-S159. PubMed 1490740

Collection Details:

Patient Preparation:

Patient should be instructed on the proper collection of a clean catch midstream urine specimen. Avoid contamination with normal flora from skin, rectum or vagina. If a clean catch urine cannot be obtained from an infant, obtain a bagged specimen: clean area as for a clean catch, attach U-bag, and put collected urine into a sterile container.

Clean catch specimen: Have patient urinate into a small clean disposable cup (styrofoam or “Dixie”). Afterward, collection site staff can transfer the urine to the urine culture transport tube using the special collection straw-puncture device designed for use with the Vacutainer® tubes. The numbers of bacteria in a clean unused cup are so few as to be inconsequential when the urine transport stabilizer is added. Thoroughly instruct patient for proper collection of a “clean catch” specimen. Patient must be instructed to thoroughly cleanse skin and collect a midstream specimen. The patient should be instructed to follow the directions provided with the urine collection kit as follows.

Catheterized specimen: Refers to an “in and out” catheter that is placed into the bladder solely for collection of the specimen and then withdrawn. Do not collect urine from the drainage bag when an indwelling catheter is in place because growth of bacteria can occur in the bag itself. Rather, clean catheter with an alcohol sponge, puncture with a sterile needle, and collect in sterile syringe. Catheter tips are contaminated by the urethra as they are withdrawn; do not culture them.

Male: Wash hands thoroughly with soap and water. Rinse them well and dry with a paper towel.

• Tear open the towelette packages so that the towels can be easily removed with one hand as they are needed. Do not touch any of the inside surfaces of the collection cup.

• Pull back the foreskin to expose the head of the penis completely.

• Wash the head of the penis thoroughly using first one towelette then the other. Discard the used towelettes into the toilet bowl.

• Pass a small amount of urine into the toilet bowl, then pass a sample into the container. Do not allow the container to touch the legs or penis. Keep fingers away from the rim and inner surface of the container. Fill the container half full.

• The urine specimen should be transferred to the Vacutainer® tube within 10 minutes of collection.

Female: Wash hands thoroughly with soap and water. Rinse them well and dry with a paper towel.

• Tear open the towelette packages so that the towels can be easily removed with one hand as they are needed. Do not touch any of the inside surfaces of the collection cup.

• Remove undergarments and sit on the toilet seat with legs spread widely apart.

• With one hand, spread labia apart to expose the vulva. Keep this hand in place during the washing and urinating procedure.

• Use one towelette to wash the vulva well passing the towelette only from front to back, not back and forth. Repeat this procedure using the second towelette. Discard the used towelettes into the toilet bowl.

• Begin urinating into the toilet bowl then, without stopping the stream, insert the collection cup to collect the specimen. Do not allow the container to touch the legs, vulva, or clothing. Keep fingers away from the rim and inner surface of the container. Fill the container about half full.

• The urine specimen should be transferred to the Vacutainer® tube within 10 minutes of collection.

Collection Instructions:

Specimens from other sources, such as genital, stool, urine, upper and lower respiratory specimens, cannot be cultured under the aerobic bacterial culture test number. If specimens are incorrectly submitted with an order for aerobic bacterial culture, the laboratory will process the specimen for the test based on the source listed on the test request form. The client will not be telephoned to approve this change, but the change will be indicated on the report.

Vacutainer® gray-top urine culture transport tube with preservative (preferred).

If less than 4 mL of urine is collected, usually from pediatric and geriatric patients or from a catheter, submit refrigerated in a sterile, screw cap container or tube. Do not submit low volume urine specimens in underfilled gray top tubes.

Clean catch midstream collection. First morning specimens yield highest bacterial counts from overnight incubation in the bladder, and are the best specimens.

Maintain specimen at room temperature.